Note:
Secure the connection cable onto the control board with the holder (clamper).
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
12.2.4.1
Wire Stripping and Connecting Requirement
Wire stripping
No loose strand
when inserted
RISK OF FIRE
JOINING OF WIRES
MAY CAUSE
WARNING
OVERHEATING
AND FIRE.
Do not joint wires
OR
12.2.4.2
Cutting and flaring the piping
1
Please cut using pipe cutter and then remove the burrs.
2
Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end
down to avoid the metal powder entering the pipe.
3
Please make flare after inserting the flare nut onto the copper pipes.
Terminal
Board
Earth wire
longer than
others
AC wires
for safety
reason
Tape
Indoor & outdoor
connection cable
Escapement
Connection cable
Indoor/outdoor
connection
terminal board
5 mm
or more
(gap between wires)
OR
37
Holder
Indoor & outdoor
connection cable
Outdoor unit
Conductor
fully inserted
over inserted
ACCEPT
OR
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national
wiring rules.
Conductor not
Conductor
fully inserted
PROHIBITED
PROHIBITED