18.2.3 Steps to remove the vertical airflow direction louver (for the lower side)
1. Check that the product is plugged in.
2. Hold down the Eco Navi button on the remote
control for 5 seconds and wait until the
vertical airflow direction louver opens and
stops automatically.
Unplug after it stops.
※ Please operate with the power
unplugged from this point.
3. Take off the vertical airflow direction louver
(for the lower side)
Pinch the tab of the fixed lock on the right
side.
Slide it to the left side and remove the
right vane axis from the right stepping
motor axis.
Slowly take down the right side of the
vertical airflow direction louver (for the
lower side) to the point where it does not
contact the corner of the front grill. Slide
the vertical airflow direction louver (for
the lower side) to the right side and then
remove it from the main unit central axis
and the left stepping motor axis.
※ Slide it to the right to remove.
※ Pinch the tab and slide it to the left to remove.
【Removal completed】
153
※ Take it down to the position
where the right side of the
vertical airflow direction
louver (for the lower side)
does not contact the corner
of the front grill.