Panasonic CS-VZ9SKE Service Manual page 80

Hide thumbs Also See for CS-VZ9SKE:
Table of Contents

Advertisement

14.16.1.2
Information Log
The signal from Infrared sensor will be log to human activity database for further analysis.
14.16.1.3
Human Position Analysis
According to Area of Living, frequency of activity, the system will analyze the human position away from the
indoor unit.
14.16.1.4
Human Activity Level Judgment
Human Activity Level is judged based on the frequency of pulses detected by the infrared sensor within a
timeframe. The activity level will be categorized into High, Normal or Low level.
When a pulse is detected within this timeframe, the status of human presence is judge.
When there is no signal detection continues for 30~60 minutes, the result of activity amount status is "Low"
consecutively for 5 cycles the status of human absence is judged.
14.16.1.5
Determination of Presence or Absence
Human presence status shall be determined based on the human presence status of each area.
When all area has been detected absent for more than 120 minutes then it will judge as absence.
14.16.1.6
Area of Living Classification Judgment
The system is able to judge area of living according to human activity database, classified as following:
Living Area - In front of television, dining table, etc.
o
Walkway - Human detection is relatively less.
o
Non-Living Area - Near windows, wall, etc.
o
14.16.1.7
Target Area and Position Judgment
By default, the system will judge the indoor unit installation position according to human activities and will reset
the louver center position:
Non-Living Area at Position A - Indoor unit is installed at left side of the room, louver center position set to
o
right side.
Non-Living Area at Position C - Indoor unit is installed at right side of the room, louver center position set to
o
left side.
Other than above - Indoor unit is installed at center of the room, louver position set to center.
o
Every 4 hours, the Target Area and Position Judgment will restart.
If the indoor unit installation position is set by remote control, the above judgement will be ignored.
14.16.2 Setting Temperature and Fan Speed Shift
 Cooling Dual Sensor
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Mode
COOL/DRY
HEAT
Human
Low activity
Set
temperature
Normal activity
+1°C
80
High activity
Absent
-2°C
+2°C
-2°C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-vz9skeCu-vz12skeCs-vz12ske