Panasonic CS-VZ9SKE Service Manual page 166

Hide thumbs Also See for CS-VZ9SKE:
Table of Contents

Advertisement

18.3.8.3
Process 2 (Removing brazing point)
1
Remove tape (poly-e foam) from piping prior to removing the brazing point.
Caution
Protection from the brazing flame should be considered during replacing the parts.
Firstly disconnect the which pipe entering to aluminium electric heater, compressor suction and the
compressor discharge pipes.
18.3.8.4
Separate Compressor from Aluminium Electric Heater
1
Take out blocks of compressor and aluminium electric heater from base pan.
2
Remove the fixing screw for clamping bracket of the aluminium electric heater (2 pieces) and lift the bracket
to remove.
3
Separate the aluminium electric heater from compressor.
Compressor suction
Aluminium electric
heater outlet
Compressor discharge
Aluminium electric
heater inlet
Screw for clamping bracket
166
tape (poly-e foam)

Hide quick links: