When sensor is not set:
Cooling
Heating
Dry
14.16.3.2 Human Activity Sensor Check Mode
1
Conditions to start the mode
The infrared sensor check mode starts when all of the following conditions are fulfilled / satisfied:
a.
The infrared sensor error is not being detected.
b.
Not in Demo mode.
c.
An error of Error Level 20 or higher is not present.
d.
The signal for infrared sensor check is received.
2
Conditions to end the mode
The infrared sensor check mode ends when any of the following conditions is met:
a.
A signal other than the signal for infrared sensor check is received; or the Auto OFF/ON button is
pressed → The signal received is followed.
b.
5 minutes have elapsed since the signal for infrared sensor check was received → The mode is stopped.
c.
The infrared sensor error is confirmed → The mode is stopped.
d.
An error of Error Level 20 or higher has occurred → Follow the processing of each error.
Auto mode air conditions whole room
Air discharge controlled
Horizontal vane : swings
Vertical vane : swings
When cool
Air flow controlled
Vertical vane : swings
wind strong
Vertical vane : swings
When "Powerful" or "More" is set, is cools
(heats) the entire room quickly
wind strong
When heated
wind strong
to cooling
82
When hot
When cooling
Air flow controlled
Vertical vane : swings
When cool
When heated
Air flow controlled
(cannot be set)