Model
Pipe Diameter (Liquid / Gas)
Standard length
Length range (min – max)
I/D & O/D Height different
Additional Gas Amount
Length for Additional Gas
Inner Diameter
Drain Hose
Length
Fin Material
Indoor Heat
Exchanger
FPI
Fin Material
Fin Type
Outdoor Heat
Exchanger
Row × Stage × FPI
Size (W × H × D)
Power Supply
Power Supply Cord
Thermostat
Protection Device
Cooling
Indoor Operation
Heating
Range
+8/10°C HEAT
Cooling
Outdoor Operation
Heating
Range
+8/10°C HEAT
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Specifications are subjected to change without prior notice for further improvement.
Indoor
Outdoor
mm (inch)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
mm
mm
mm
A
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
12
CS-VZ9SKE
CU-VZ9SKE
6.35 (1/4) / 9.52 (3/8)
5.0 (16.4)
3 (9.8) ~ 15 (49.2)
5.0 (16.4)
20 (0.2)
7.5 (24.6)
16.2
650
Aluminium (Pre Coat)
20.5
Aluminium (Pre Coat)
Corrugated Fin (2LT-C6S-L)
2 × 32 × 19
809.5:789.7 × 586.24 × 25.2
Indoor Power Supply
Nil
Electronic Control
Electronic Control
DRY BULB
32
16
30
16
10
16
43
-10
24
-30
-30
WET BULB
23
11
26
18