Provides specifications for the operating environment.
Operating: 0°C to 40°C
0 to 40 degrees C (0 to 2500 ft)
0 to 35 degrees C (2500 to 5000 ft)
0 to 30 degrees C (5000 to 10000 ft)
Storage temperature range: -10°C to 60°C
Humidity range: 10% to 85% RH (maximum), non condensing
Storage humidity range: 5% to 90% RH (maximum), non condensing
Operating altitude: 10,000 ft maximum

Power requirements

Learn the power requirements for the projector.
Parameter
Rated voltage
Input 1
Input 2
Rated current
Input 1
Input 2
Line frequency
AC input coupler
Input 1
Input 2
Inrush current
Maximum power consumption
Input 1
Input 2

Warnings

If the condition of the power input is abnormal, the projector displays the following warning:
Incorrect AC power detected. The projector is running in reduced brightness mode (ECO 2).
Ensure the proper power is being provided to the selected projector input.
HS Series User Manual
020-000883-03 Rev. 1 (07-2016)
Requirement
100V-120V
200V-240V
14A
7A
50/60Hz
C20
C14
80A max
1500W
1400W
Specifications