Off-Board Outputs; B308 Octo-Output Module; Sdi2 Address Settings; Supervision - Bosch B9512G Installation And System Reference Manual

Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panels
11

Off-board outputs

The control panel supports off-board outputs using the B308 Octo-output Module and the
through using a B600 Retrofit ZONEX Module.
11.1

B308 Octo-output Module

The B308 is an eight output expansion device that connects control panel through the SDI2
bus. This module is supervised for the connection to the SDI2 bus. It provides eight
independently controlled outputs. Each output can operate as either normally open or
normally closed. You can configure the function for each output on the module individually.
Refer to Output Parameters in RPS Help or the control panel Program Entry Guide.
B9512G control panels support up to 59 modules to provide 472 outputs. B8512G control
panels support up to 9 modules to provide 72 outputs.
B308 Octo-output Modules connect to the SDI2 bus on control panel using terminals 27
through 30 (or 23 through 26 if configured for SDI2), or using the SDI2 interconnect wiring
connector. You can connect more than one module to the control panel by wiring them in
parallel. This section includes basic installation instructions. For detailed installation
instructions, refer to the Octo-output Module (B308) Installation and Operation Guide.
Notice!
Do not connect fire and non-fire devices to the same B308 Octo-output Module.
Outputs overview
Each module output provides a Form C dry contact rated for .001 to 1.0 A at 5 to 24 VDC
(resistive load). Normally-open, common, and normally-closed terminals are available for each
relay output. When an individual output is activated, continuity exists between the normally
open and common terminals. When the output is not activated, continuity exists between the
normally closed and common terminals.
11.1.1

SDI2 address settings

Notice!
The module reads the address switch setting only during module power up. If you change the
setting after you apply power to the module, you must cycle the power to the module in order
for the new setting to take effect.
If multiple B308 modules reside on the same system, each B308 module must have a unique
address.
The number of outputs allowed by the control panel determines the valid addresses.
For valid output numbers, refer to B308 address settings, page 169.
11.1.2

Supervision

The control panel enables supervision of B308 Octo-output Modules on the SDI2 bus when the
Output Source of an off-board output is set to Octo-output.
With any failure to receive an expected response from the module, all keypads show a system
fault. The control panel sends a module trouble report to the central station (if configured for
module trouble reports).
Bosch Security Systems, Inc.
Installation and System Reference Guide
Off-board outputs | en
69
2016.06 | 08 | F.01U.303.996