D9210C; Card Reader Wiring - Bosch B9512G Installation And System Reference Manual

Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panels
Caution!
Remove all power (AC and battery) before making any connections. Failure to do so might
!
result in personal injury and/or equipment damage.
Install the module
1.
2.
3.
Wire to the control panel
When you wire an SDI2 module to a control panel, you can use either the terminal strip
labeled with PWR, A, B, and COM to wire to corresponding terminals labeled 27 through 30
(or 23 through 26 if configured for SDI2) on the control panel, or you can use the interconnect
wiring connector and the included interconnect cable.
For terminal wiring, use 18 AWG to 22 AWG (1.02 mm to 0.65 mm) wire.
Notice!
Use either the terminal strip wiring or interconnect wiring to the control panel. Do not use
both. When connecting multiple modules, you can combine terminal strip and interconnect
wiring connectors in series.
The B901 module also connects to the SDIx bus and functions as a D9210C when SDIx is
configured as SDI. Use either the terminal strip wiring or interconnect wiring to the control
panel.
15.2

D9210C

The D9210C Access Control Interface Module is a four-wire SDI powered device providing
connections for an access door point and door strike. Each D9210C supports one door to
control access. You can independently configure each access door.
Notice!
The module reads the address switch setting only during module power up. If you change the
setting after you apply power to the module, you must cycle the power to the module in order
for the new setting to take effect.
SDI address settings
If multiple access control modules reside on the same system, each access control module
must have a unique address.
For valid addresses, refer to D9210C address settings, page 172.
Installation
For detailed installation instructions, refer to Access Control Module (D9210C) Installation and
Operation Guide (P/N: F01U215244).
15.3

Card reader wiring

To wire the access control module to a card reader, refer to the card reader instructions
printed on or shipped with the reader.
Bosch Security Systems, Inc.
Set the module address using the address switches before you install it in the enclosure.
Install the module in the enclosure with the control panel or in an adjacent enclosure that
is within the distances rated for the module: 1000 ft (305 m) with 18 AWG to 22 AWG
(1.02 mm to 0.65 mm) wire.
Use the screws provided with the module to secure the module in the enclosure.
Installation and System Reference Guide
Access control | en
87
2016.06 | 08 | F.01U.303.996

Hide quick links: