Motion Tolerance
Rotational Sensitivity
Viewing Angle
Ambient light
Illumination LEDs
Aiming
Symbologies supported
Size
Weight
Operational Input Voltage
Operating Temperature
Storage Temperature
Humidity
Shock

7.3.3.1 HHP 5000 Decode Zone

Performance Focal Point
SR
4 in. (10.2 cm) per second
360°
±40°
Total darkness to 100,000 lux (full sunlight)
626 nm ±30 nm
LEDs: 526 nm ±30 nm
Laser: 650 nm ±10 nm
2D: PDF417, MicroPDF417, MaxiCode, Data Matrix, QR Code,
Aztec, Aztec Mesa, Code 49, UCC Composite
Linear: Code 39, Code 128, Codabar, UPC, EAN, Interleaved 2
of 5, RSS, Code 93, Codablock
Postal: Postnet (US), Planet Code, BPO 4 State, Canadian Post,
Japanese Post, KIX (Netherlands) Post
1.78 cm Depth x 2.79 cm Width (without mounting tabs) x 1.21
cm Height
0.7 in. Depth x 1.1 in. Width (without mounting tabs) x 0.475 in.
Height
5.9 grams (.21 ounces)
Imager: 3.3 VDC ±5% (23°C)
Illumination + Aimer 5300: 3.0 VDC to 5.5 VDC (23°C)
-30° to +50°C (-34° to 122°F)
-40° to +70°C (-40° to 158°F)
up to 95% RH, non-condensing at 122° F (50°C)
18 shocks of 3,500 G for 0.5 msec at 23°C (73° F)
7 inches (17.8 cm) from lens plate