2.4.1.1.1 Switch Settings and LED Indications
Switch
SW1 - Load
Switch
Switch
SW1 - Load
Switch
Switch
SW6 - CCPU
Setup Switch
(Normally, these
switches should
be left alone
unless specified)
Chapter 2
With a system restart or a system reset while holding the Load/SW1 switch:
USB Memory Status
When USB Memory is not installed:
When USB Memory is installed:
When an unauthorized USB is installed:
With the system power on, pressing the Load/SW1 switch:
USB Memory Status
When USB Memory is not installed:
When USB Memory is installed:
When an unauthorized USB is installed:
Switch Setting
SW6-1:
On = Unused
Off = Normal
SW6-2:
On = Test Mode
Off = Normal
SW6-3:
On = Used
Off = Not Used
SW6-4:
On = Normal
Off = ICE Mode
The LED indications on the CCPU represent the following:
●
RUN LED 1 = Indicates the CCPU is operating (green)
●
LED 2, 3 and 4 = Indicates alarms (red)
●
LED 5 = Indicates the USB memory connection status (red)
(LED off when no USB memory installed)
Refer to Program 90-10 : System Alarm Setup for details on assigning alarm LEDs.
Chapter 2 - PCB Installation and Startup
Operation
•
Cold Start occurs.
•
USB Memory contents loaded.
•
System does not start and an "Illegal USB device is
connected" alarm is recorded.
Operation
•
No operation.
•
USB Memory contents loaded.
•
No operation.
Operation
•
VMDB Modification
•
Test Mode
•
RS-232C Select
•
Reset Configuration
2 - 17