Installing The Power Failure Telephones: - NEC UX5000 Hardware Manual

Ip communication server
Hide thumbs Also See for UX5000:
Table of Contents

Advertisement

Chapter 4 - Telephones and Optional Equipment
4.15.3

Installing the Power Failure Telephones:

1.
2.
3.
4.
Trunk I/F Circuit #2
Trunk I/F Circuit #1
CN2(COIU)
Analog Trunk
From Central Office
for Interface Circuit.
#1-#4
CN3
SLT I/F for
Power Failure
Transfer
#1-#2
BUSY LED
(Status for Trunk Lines)
ON: Trunk in Use
OFF: Idle
LIVE LED
(Status LED)
The 4COIU PCB with 4COIUDB is shown.
4 - 54
Connect an RJ-61 connector to the COIU PCB installed in the UX5000 system.
Install a modular jack for each single line telephone supporting PF operation. The modular
jack should be within six feet of the phone.
For each extension, run one-pair 24 AWG station cable from the cross-connect block to a
modular jack.
Terminate the extension leads to GRN/RED of the modular jack. Terminate the unused leads
to the jack.
Trunk I/F Circuit #3
CN5
Pin Number
Location
8
7
6
5
2
1
Figure 4-19: POWER FAILURE CIRCUIT INSTALLATION