Completing The Cp8 Blade Replacement - IBM System Storage SAN384B-2 Installation, Service And User Manual

Hide thumbs Also See for System Storage SAN384B-2:
Table of Contents

Advertisement

Restarting system.
The system is coming up, please wait...
.
.
.
Fri Jun 18 14:53:13 2011: Doing firmwarecommit now.
Please wait ...
Fri Jun 18 14:55:27 2011: Firmware commit completes successfully.
Validating the filesystem ...
Fri Jun 18 22:36:05 2011: Doing firmwarecommit now.
Please wait ...
Fri Jun 18 22:36:48 2011: Firmware commit completes successfully.
2011/06/18-14:56:50, [SULB-1004], 908, SLOT 4 | CHASSIS, INFO,
SAN384B-2, Firmwarecommit has completed.
2011/06/18-14:56:50, [SULB-1036], 909, SLOT 4 | CHASSIS, INFO,
SAN384B-2, The new Version: Fabric OS v7.0.1
2011/06/18-14:56:50, [SULB-1002], 910, SLOT 4 | CHASSIS, INFO,
SAN384B-2, Firmwaredownload command has completed successfully.
Note: The time stamp on the co-cpu may not be in sync with the main cpu on
the blade. This is not a cause for concern.
8. Log back in to the standby CP blade and enter firmwareDownloadStatus on
the standby CP blade to validate a successful commit. This may take up to 10
minutes.
9. If you are upgrading through several levels of the Fabric OS, repeat step 4
through step 8 as often as necessary based on the path outlined in the table
above. Otherwise, proceed to step 10
10. Log out of the standby CP blade and log in to the active CP blade.
11. Proceed to "Completing the CP8 blade replacement."

Completing the CP8 blade replacement

Complete the steps to complete the CP8 control blade replacement procedure.
1. Enter haEnable to re-enable HA on the active CP blade
Note: haEnable will cause the standby CP blade to reboot. Wait until the
power cycles and the POST completes before moving to the next step.
POST is complete when the Status LED on the CP blade returns to a
steady green state.
2. Enter haShow and verify that the command output includes "HA Enabled,
Heartbeat Up". If it is not yet enabled, re-enter the command until you have
verified that redundancy is achieved.
DCX_124:admin> hashow
Local CP (Slot 5, CP1) : Active
Remote CP (Slot 4, CP0) : Standby, Healthy
HA Enabled, Heartbeat Up, HA State Synchronized
3. Enter firmwareShow to verify that the firmware version has been updated and
that the versions are the same on the two CP blades. Not all slot numbers are
shown in this example.
384B_2:admin> firmwareshow
Slot Name
-----------------------------------------------------------
2 FX8-24
4 CP0
Appl
Primary/Secondary Versions
FOS
v7.0.1
v7.0.1
FOS
v7.0.1
v7.0.1
Chapter 5. Removing and installing components
Status
STANDBY
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents