POWERHEAD
INSTALLATION
-
25/30
ALL MODELS
Connect the overboard water indicator hose to the
fitting on the exhaust cover. Secure the hose in
the J-clamp.
Connect the fuel hose to the fuel pump with a new
tie
strap.
001007
Install the throttle control lever.
21580
216
Slide the throttle control rod through the nylon
block on the throttle control lever. Insert the pin in
the end of the rod. The offset on the nylon block
must face forward.
Place the nylon bushing on the stud of the throttle
control lever. Engage the armature plate link on
the stud
.
Place the washer over the stud and
engage the spring.
1.
Throttle control rod
21579
2
.
Pin
3.
Armature plate link
4.
Spring
Install the manual starter lockout cable bracket
(R Models only).
1.
Bracket
21014
Install the manual starter. Refer to Manual Starter
INSTALLATION on
p.
303.
Adjust the neutral start switch (TE Models only).
Refer to NEUTRAL START PROTECTION on
p.
178.
Adjust the shift
lever.
Refer to Shift Linkage
Adjustment on p. 177.
IMPORTANT:
To avoid permanent powerhead
damage, instruct operator to repeat the outboard
Break-In (10 Hours) on p. 52.