Johnson J10RLSRD Service Manual page 184

Table of Contents

Advertisement

Insert a paper clip into plunger.
Remove the pin and washer from the actuator
cam link. Disengage the link from the shift actua-
tor cam.
1
1.
Pin and washer
47171
ALL MODELS
Remove the ground lead from the powerhead.
Using Special 1/2 in. Box Wrench, PIN 322700,
remove port and starboard powerhead retaining
nuts with washers.
1.
Port retaining nut and washer
47173
1.
Starboard retaining nut and
washer
POWERHEAD
REMOVAL - 25/30
47174
Remove the four screws retaining the powerhead
to the exhaust housing.
1.
Screws
20984
Move the powerhead sideways to break the gas-
ket loose and remove from midsection. Remove
the inner exhaust tube from the powerhead.
2
1.
Inner exhausttube
1415
2.
Gasket
Place the powerhead in a suitable holding fixture
and remove all carburetor, ignition, and electrical
components from the powerhead. To simplify
reassembly and wiring installation, layout the var-
ious screws and clamps in order of their proper
location.
183