5. ELECTRIC FUSES AND THERMAL CUT-OUTS

The machine is fitted with the following electrical protection systems:
Power fuses arranged in the electrical box, to protect against short-circuiting
thermal trip units arranged on the outside of the handlebars, to protect the following motors:
1. 30A trip unit (1) for the base motor
2. 20A trip unit (2) for the suction motor
In the event of malfunctioning, check a thermal cut-out has not intervened. If the motor overheats, its
thermal cut-out intervenes to block the electricity supply. Wait a few minutes until it has cooled down, then
press the specific trip unit button to reactivate the power supply and motor operation.