47. THE SUCTION MOTOR DOES NOT FUNCTION

1.
Check whether the recovery tank is full and, if necessary, empty it
2.
Check the float switch on the suction cap (see also "CLEANING THE RECOVERY TANK" in the
chapter "DAILY MAINTENANCE")

48. THE BRUSH MOTOR DOES NOT WORK

ATTENTION To avoid damaging the floor, the motor only starts up when the machine is moved
forwards
1. Check that the base is lowered during the forward movement with the right lever (1) turned
clockwise.
2. The operator must be properly seated in the driving position
3. Check no thermal protection device has intervened.
4. Check the correct connection of the motor to the terminal under the footboards.

49. THE MACHINE DOES NOT START

1.
Check that connector (1) is connected to the batteries
2.
Check the key switch is ON/I
3.
Check that batteries are charged

50. ELECTRIC FUSES AND THERMAL CUT-OUTS

In addition to general 80 A fuses, the machine is also fitted with self-restoring safety fuses located on
the boards in the electric system that interrupt the power supply to the brush and suction motors when
the machine exceeds the predetermined load. To restore the power supply to the motor, switch off the
machine and wait for the fuses to cool down (about 40 seconds). If the switch disconnects the current
several times in a row, contact the COMAC technical assistance centre.