132 Errors - Lexmark MS510 Service Manual

Hide thumbs Also See for MS510:
Table of Contents

Advertisement

LVPS service check
Action
Step 1
a
Check the power cord for continuity. If necessary, replace.
b
Make sure the nominal voltage source is within specification. See
"Electrical specifications" on page
Does the problem remain?
Step 2
Check if the power supply cable is properly connected to the controller
board.
Is it properly connected?
Step 3
a
Turn off the printer.
b
Remove the power cord.
c
Measure the resistance between terminals A and D of the power
supply socket.
Is the resistance approximately 30 ohms?

132 errors

132 error messages
Error code
Description
132.01
TDS baseline too low.
132.02
TDS baseline too high.
132.03
TDS baseline excessive range.
132.16
TDS calibration at maximum.
132.17
TDS calibration too low.
132.18
TDS calibration too close to baseline.
132.32
PC drum measurement too high.
132.33
PC drum measurement too different from calibration.
132.34
PC drum measurement too close to baseline.
303.
Diagnostic information
98
Yes
Go to step 2.
Go to step 3.
Contact your next level
of support.
Action
Go to
"Toner density sensor service check" on
page
99.
4514-6xx
No
The problem is solved.
Reseat the cables.
Replace the power
supply. See
"Power
supply removal" on
page
240.