Hardware Error Messages - Oki OKILAN 6100E+ User Manual

High performance ethernet network print server
Table of Contents

Advertisement

Section 4 - Appendix A - Troubleshooting
OkiNet for TCP/IP - Winsock Errors
• If you see an error before OkiNet for TCP/IP appears
on the screen, try setting a host name in the hosts file
in the Windows directory (check the documentation
for your Windows TCP/IP stack).
• If you have difficulty seeing a particular OkiLAN
6100e+, try moving the device onto the same subnet
as the computer running the utility.
• If OkiNet for TCP/IP gives you the Winsock error:
Could not bind to socket, use the Special Options
dialog under the File menu to change the Discovery
UDP Port to a different port number.

Hardware Error Messages

ST: Cable not connected
Self-test has determined that the network cable is not
connected.
• Check the cable connection to the OkiLAN
6100e+.
• Move the OkiLAN 6100e+ to another known
working node.
If you find the cable is connected and you are still
receiving this message or any other "ST:" error
message, power cycle the OkiLAN 6100e+. If the error
continues, call Okidata Customer Support at
1-800-OKIDATA (1-800-654-3282).
System CRC Failed
The OkiLAN 6100e+ has failed.
• Power cycle the OkiLAN 6100e+ once. If the error
continues, call Okidata Customer Support at
1-800-OKIDATA (1-800-654-3282).
IV - 52
OKI OkiLAN 6100e+ User's Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pm4410Okipage18Okipage24dxOkicolor8

Table of Contents