Removing the PCBA - Floor Cabinet Model
After removing the side panel, the card cage can be accessed. To remove the Logic C PCBA
from the card cage, perform the following instructions and refer to Figure 3-3.
1.
To lower the card cage (A), loosen but do not remove the release wing nut (B) on the right
side of the card cage and gently pull the front edge of the cage down.
2.
Locate the Logic C PCBA (C); the names of the PCBAs are printed on the card cage.
3.
Cut the tie wrap restraints (D) if present.
4.
Snap out the top and bottom ejector levers (E) to release the PCBA from the edge con
nector.
5.
Gently slide the PCBA out of the card cage.
6.
Make or verify the required jumper configuration change(s). See Table 3-2 on page
3-13.
Configuration
Figure 3-2. Side Panel Removal - Floor Cabinet Model
3-9