Paper Instruction (PI) - Optional EVFU control signal from the host with the same timing as
the data lines. Sensing the PI line is controlled by printer configuration.
NOTE: The PI Line must be disabled (configuration option selected from the front
panel) if the host computer does not drive or control the PI Line. If the line is not con
trolled by the host and sensing is enabled, rapid paper slewing will occur.
Data Line 1
Data Line 2
Data Line 3
Data Line 4
Data Line 5
Data Line 6
Data Line 7
Data Line 8
Paper Instr.
Data Strobe

Parallel Interface Configuration

The printer is configured at the factory for the type of interface used, either parallel or serial.
However, certain user selectable configuration options are available. The following configura
tion parameters can be verified or changed as necessary to meet specific application require
ments:
Input buffer size
n
Sense of Data Line 8
n
Sense of the Paper Instruction line
n
Data Polarity
n
Printer Error Polarity
n
Fast Busy
n
These parameters are displayed under the Application Compatibility and Interface Compati
bility menus selectable from the control panel. This data may be latched on either the leading
or the trailing edge of the Data Strobe signal by selecting the appropriate jumper on the Logic
7-4
Table 7-2. Centronics Interface Connector Pin Assignments
INPUT SIGNALS
SIGNAL
PIN
2
Return
20
3
Return
21
4
Return
22
5
Return
23
6
Return
24
7
Return
25
8
Return
26
9
Return
27
15
Return
14
1
Return
19
OUTPUT SIGNALS
SIGNAL
PIN
ACKNLG
10
Return
28
SLCT/IONL
32,13
PE
12
+5 Volts
(Test Only)
18
Busy
11
Return
29
Chassis
16,17
Ground
33
Not Used
30,31,
34,35, 36