Platen Restraints Removal
Platen restraints include the platen restraint screws (one at each end of the platen), the Forms
Thickness Adjustment lever tie wrap, and the wire paper guide tie wrap. To remove these re
straints, perform the following instructions and refer to Figure 10-5.
1.
Raise the printer cover.
2.
Remove the two platen restraint set screws (A) with the 3/32 inch hex wrench.
3.
Cut and remove the tie wrap (B) securing the Forms Thickness Adjustment Lever.
4.
Cut and remove the tie wrap securing the paper guide and power cord.
Figure 10-5. Platen Restraint Removal - Floor Cabinet Model
Front Shock Mount Restraint Screw Removal
As shown in Figure 10-6, two of the six shock mount restraint screws (A) are accessed through
the front of the printer. The restraint screws are tagged with a red warning label. Open the front
cabinet door (B) and remove the restraint screws using the 3/8" nut driver.
10-6
Installation