Complete the following steps:
1. Information only; no action is required.
I.580A4 [I.580A4]
Explanation: Memory population change detected. DIMM Population Change Detected
Severity
Info
User Response
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected,
then please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
I.580A5 [I.580A5]
Explanation: Mirror Fail-over complete. DIMM number % has failed over to to the mirrored copy. DIMM
Mirror Fail-over Detected
Severity
Info
User Response
Complete the following steps:
1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
I.580A6 [I.580A6]
Explanation: Memory spare copy has completed successfully. Spare Copy Complete
Severity
Info
User Response
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected,
then please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
S.1100B [S.1100B]
Explanation: CATERR(IERR) has asserted on processor %. Processor CATERR(IERR) has asserted
Severity
Error
User Response
Complete the following steps: