Attaching a TNC or N Connector to
RG214 Cable
These instructions explain how to terminate an RG214 RF cable with a TNC or
N-type connector.
Refer to the following diagram while performing the steps in this procedure.
Do as follows:
1. Be sure all of the connector parts listed below and shown on the following
page are provided in the connector kit:
A
Connector Body
B
Rubber Gasket
C
Clamp
D
Nut
E
Wide Insulator
Appendix D
F
Washer
G
Inner Contact
H
Narrow Insulator
I
Bushing
D