C.9.2 Ground cable - connection
The ground cable must be mounted parallel (and in close proximity) to the
shielded coax cable thus minimizing ground loop problems. If possible, route
the coax cable and the ground cable in metal conduits bonded to the hull or
within a mast (depending on the actual installation).
The ground cable must be connected at one of the mounting/grounding bolts
on the antenna. Use bolts and washers of stainless steel and seal the joint
with protective coating to avoid corrosion. If the antenna is to be isolated from
the mounting base, shoulder bushes and washers must be used - see
page 136.
In the below drawing, vibration isolators are mounted.
At the other end, connect the ground cable at the terminal grounding kit.
Appendix C: Grounding and RF protection
Separate ground cable
Vibration isolator
Plain washer (stainless steel)
Ground cable
Serrated washer (stainless steel)
Plain washer (stainless steel)
Spring washer (stainless steel)