DAC-LTM/-RLTM External Clock Interface

The following applies to all DAC LTMs and RLTMs with an external clock port:
The external clock cicuitry contains a standard T1/E1 LIU device with receive
TIP/RING terminated at 120 ohms (incoming twisted pair).
T1 clock rate = 1.544 MHz
E1 clock rate = 2.048 MHz
Port is hardwired for Bipolar Mode only.
Port uses B8ZS/HDB3 encoding/decoding.
The external clock port m
ITU I.431, G.703, G.736, G.775 and G.823; ETSI 300-166 and 300-233; and AT&T Pub
62411.
296-1011-202 Rel. 5.0, Doc. Rev. 02.01

DAC-LTM/-RLTM External Clock Interface

eets or exceeds specifications in ANSI T1.403 and T1.408;
Technical Specifications