Nortel Server 1005r Maintenance And Diagnostics page 173

Nortel networks network device maintenance and diagnostics
Hide thumbs Also See for Server 1005r:
Table of Contents

Advertisement

June 2007
18
Line up the two grooves on the back lip of the PCI riser assembly
with the pins on the rear panel as shown in the following illustration.
19
Hold the PCI riser assembly by the two blue handles (A) and push
the assembly into the server board. Refer to "PCI riser card
assembly" on page 169.
ATTENTION
Figure 50: PCI riser assembly rear studs and slots
20
Reconnect the DS30X cable or cables to the MPB96 card or cards.
You must reconnect each cable to the same MPB96 card it was
previously connected to. Use the labels you applied as a guide.
21
Replace the chassis cover.
22
Take the ESD strap off.
23
Power up the server and log on to Windows.
1005r Server Maintenance and Diagnostics
If the PCI riser assembly is not fully seated, the server can
malfunction.
Replacing or adding voice processing boards
173