Nortel Server 1005r Maintenance And Diagnostics page 117

Nortel networks network device maintenance and diagnostics
Hide thumbs Also See for Server 1005r:
Table of Contents

Advertisement

June 2007
Figure 22: Hard disk drive location in carrier
10
With the black lever in the fully open position, slide the drive
assembly into the chassis.
11
Insert the replacement drive in the bay. The green latch at the front
of the drive carrier must be to the right. Do not push on the black
drive carrier lever until the lever begins to close by itself.
12
When the black drive carrier lever begins to close by itself, push on
it to lock the drive assembly into place.
13
Take the ESD strap off.
14
Replace the front bezel.
15
Resynchronize the new hard disk. Refer to "To synchronize the
RAID after a successful PEP installation" on page 149.
1005r Server Maintenance and Diagnostics
Replacing basic chassis components
117