Replacing basic chassis components
Figure 21: SCSI hard drive carrier
5
Pivot the latch (A) into the upright position.
6
Pull out on the black lever to slide the carrier from the chassis (B).
7
Remove the new hard drive from its wrapper and place it on an
antistatic surface.
8
With the drive circuit-side down, position the connector end of the
drive so that it is facing the rear of the drive carrier.
9
Align the holes in the drive to the holes in the drive carrier and
attach it to the carrier using four screws that meet the drive vendor's
recommendation.