1.10 L
[Error Example]
ERR #100 (10000)
(1)
(2)
[Explanation]
Number in the
Example
(1)
(2)
Conditions
•
System Alarm Button
Any flexible button can be customized as the System Alarm button.
•
If an extension allowed to utilize this feature uses PC Console or PC Phone, the alarm information will
be displayed on the PC, and can be sent to the preprogrammed destination via PC Console or PC
Phone. PC Console and PC Phone use e-mail to send the information.
•
The alarm information will be logged on the Station Message Detail Recording (SMDR), if enabled
through system programming.
•
The PBX can be automatically diagnosed at a preprogrammed time everyday.
Installation Manual References
KX-TDA50
4.1.5 Troubleshooting by Error Log
KX-TDA100/KX-TDA200
4.1.5 Troubleshooting by Error Log
KX-TDA600
4.1.5 Troubleshooting by Error Log
Programming References
PC Programming Manual
2.5.7 Utility—Message File Transfer PBX to PC
2.10.5 [4-1-4] Wired Extension—Flexible Button—Type
2.10.13 [4-2-3] Portable Station—Flexible Button—Type
172
Feature Manual
Item
Error Code
Shows three-digit error code.
Sub Code
Shows five-digit sub code (XYYZZ).
X: Cabinet number (1–4)
YY: Slot number (00–11)
ZZ: Physical port number (01–16)
Description