Debug Tool - Prestigio CAVALIERE 141 Technical & Service Manual

Table of Contents

Advertisement

Prestigio Cavaliere 141
7. Maintenance Diagnostics

7.2 Debug Tool

Cavaliere 141 MB would not support Parallel Port, then we could not plug the Debug Card to PIO
Port to get the
Port 378
that are parallel connection with PIO output lines(Figure 1),when the system BIOS write the error
code to Port 378, the LEDs can show the messages.
Maybe the LEDs have not been mount on the mother board, you must place the LEDs for
getting error code.(Figure 2)
+3V
+3V
RP36
RP36
RP531
RP531
4.7K*8
4.7K*8
U19
Super
I/O
Figure1 : Circuit
error code. For the cause, Cavaliere 141 MB have reserved eight LEDs
D506 – D513
CL-190G
PIO[D0:D8]
Figure2 : 378 Port LEDs Location