National Instruments 653X User Manual page 60

High-speed digital i/o devices for pci, pxi, compactpci, at, eisa, and pcmcia bus systems
Hide thumbs Also See for 653X:
Table of Contents

Advertisement

PCLK
ACK
REQ
Data Out Valid
Parameter
Input Parameters
t
PCLK cycle time
pc
t
PCLK high pulse duration
pw
t
PCLK low pulse duration
pl
t
Setup time from REQ valid to PCLK
rs
falling edge
t
Hold time from PCLK to REQ invalid
rh
Output Parameters
t
PCLK to ACK valid
pa
t
Hold time from PCLK to ACK invalid
ah
t
PCLK to output data valid
pdo
t
Hold time from PCLK to output data
doh
invalid
All timing values are in nanoseconds.
© National Instruments Corporation
t
pw
t
pa
t
rs
t
pdo
Description
Figure 3-6. Burst Output Timing Diagram (Default)
t
pc
t
pl
3-9
Chapter 3
Timing Diagrams
t
ah
t
rh
t
doh
Minimum
Maximum
50
20
20
1
0
3
5
653X User Manual
22
28

Advertisement

Table of Contents
loading

This manual is also suitable for:

Daq 653x

Table of Contents