The mask for the pattern-matching trigger is the same as the one used for change
Note
detection. In other words, input lines significant for the pattern-matching trigger are also
significant for change detection.
© National Instruments Corporation
ACK (STARTTRIG)
STOPTRIG
REQ
Figure 2-18. Using a Start and Stop Trigger
Pattern-Matching Trigger
Instead of using an external signal on the start/stop trigger pins on the
I/O connector, you may start or stop (not both) an operation once a
user-specified digital pattern is matched.
Specify four parameters to set a pattern-matching trigger:
Whether it is a start or stop trigger
The data pattern to be detected/matched
The mask, which selects the bits of interest for pattern detection
Polarity (whether to detect data that matches or mismatches the
specified pattern)
The 653X device detects any occurrence of a specific pattern immediately
as the data comes in. When a match occurs, the 653X device starts
acquiring data. For example, if you want to start an acquisition when the
two least significant bits of your data are 1 and 0, you would specify your
trigger parameters to match those in Figure 2-19.
Pretrigger Data
2-29
Chapter 2
Using Your 653X
Posttrigger Data
653X User Manual