National Instruments 653X User Manual page 102

High-speed digital i/o devices for pci, pxi, compactpci, at, eisa, and pcmcia bus systems
Hide thumbs Also See for 653X:
Table of Contents

Advertisement

Pins
Signal Name
23, 57–58,
DIOC<0..7>
25–26,
60–61, 28
29, 31–32,
DIOD<0..7>
34, 63–64,
66–67
40
CPULL
38
DPULL
1
+5 V
11, 14, 18,
GND
20, 24, 27,
30, 36–37,
39, 41–42,
46, 49–50,
55, 59, 62,
65, 68
19, 35, 43,
RGND
56
© National Instruments Corporation
Table C-3. Signal Descriptions (Continued)
Signal
Type
Data
Port C bidirectional data lines
Port C is referred to as port number 2 in software. DIOC7 is the MSB; DIOC0
is the LSB.
Data
Port D bidirectional data lines
Port D is referred to as port number 3 in software. DIOD7 is the MSB; DIOD0
is the LSB.
Bias
Control pull-up/pull-down selection
Selection
Input signal that selects whether the 653X device pulls the timing and
handshaking control lines (REQ, ACK, PCLK, and STOPTRIG) up or down
when undriven. If you connect CPULL to +5 V on the external terminal
connector, the 653X device pulls the control lines up. If you connect CPULL
to GND or leave CPULL unconnected, the 653X device pulls the control lines
down.
See power on state the
Considerations, for more information.
Bias
Data pull-up/pull-down selection
Selection
Input signal that selects whether the 653X device pulls the data lines (DIOA,
DIOB, DIOC, and DIOD) up or down when undriven. If you connect DPULL
to +5 V on the external terminal connector, the 653X device pulls the data lines
up. If you connect DPULL to GND or leave DPULL unconnected, the 653X
device pulls the data lines down.
See power on state the
Considerations, for more information.
Power
5 V output
Line that provides a maximum of 1 A of power. This line is protected by an
onboard fuse that shuts off power when there is too much current and
automatically resets itself after current returns to normal.
Power
Ground
These lines are the ground reference for all other signals.
Power
Reserved ground
These lines offer additional ground pins. If you are using an R6868 ribbon
cable for example, these lines can be used as additional ground references. If
you are using an SH68-68-D1, however, these signals are not connected.
Appendix C
Signal Description Based on Mode Used
Power-On State
section in Appendix D,
Power-On State
section in Appendix D,
C-5
Connecting Signals with Accessories
Hardware
Hardware
653X User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Daq 653x