Daikin FCQ35B7V1 Service Manual page 282

Hide thumbs Also See for FCQ35B7V1:
Table of Contents

Advertisement

Disassembly and Maintenance
Step
1
4
Disconnect the
connector for fan motor.
For FCQ71D : Direct
connector
For FCQ100~
140D: Relay
connector
5
Remove the grounding
wire mounting screw.
6
Remove the switch box
fixing screw.
3
7
Tilt the switch box in the
direction shown by the
arrow, then draw the
entire switch box out.
5 5
5–32
Procedure
Fan motor
Grounding wire
Switch box fixing screw
(Status after removal)
Inverter PC board
(for RZP100~140D models only)
Control PC board
Power supply PC board
Part 5 – Disassembly and Maintenance
ESIE05-04
Points