Page 2
Daikin Europe N.V. is participating Daikin Europe N.V. is approved by LRQA for its Quality in the EUROVENT Certification Programme. Management System in accordance with the ISO9001 Products are as listed in the EUROVENT standard.
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Features + Leaves maximum floor and wall space for furniture, decoration + The (wired) remote control has a programmable timer and fittings + Centralised control of several units can be achieved via 3 wired + Fits flush into each ceiling remote controls + Extremely quiet in operation both indoors and outdoors...
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Specifications ELECTRICAL SPECIFICATIONS For indoor units only: FCQ35B7V1 FCQ50B7V1 FCQ60B7V1 CURRENT Nominal running current cooling/heating A See chapters RS-B + RKS-B + RXS-B Max. running current cooling/heating A See chapters RS-B + RKS-B + RXS-B...
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Wiring diagrams FCQ-B7 Notes 1. Use copper conductors only. 2. When using the central remote control, see manual for connection to the unit. Indoor 3. X24A is connected when the remote control kit is used. Wired remote 4.
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Air flow patterns FCQ35B7 Heating - air velocity distribution 4-way discharge, air flow direction: down FCQ35B7 Heating - air temperature distribution 4-way discharge, air flow direction: down 4D024116 • Split - Sky Air • Indoor Units...
Page 12
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Air flow patterns FCQ50B7 Heating - air velocity distribution 4-way discharge, air flow direction: down FCQ50B7 Heating - air temperature distribution 4-way discharge, air flow direction: down 4D024117 • Split - Sky Air • Indoor Units...
Page 13
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Air flow patterns FCQ60B7 Heating - air velocity distribution 4-way discharge, air flow direction: down FCQ60B7 Heating - air temperature distribution 4-way discharge, air flow direction: down 4D024118 • Split - Sky Air • Indoor Units...
Page 14
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Accessories Standard accessories Check if the following accessories are included with your unit. Also used as packing material Drain hose Clamp Paper pattern for installation 1 pc. 1 pc. 1 pc. Screws M5 Washer for hanging bracket Sealing...
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Control systems Wired remote control Name and function of each switch and display on the remote control ON/OFF BUTTON DISPLAY ’’ ’’ (DEFROST) Press the button and the system will start. Press the button again and the system will stop. TIMER MODE START/STOP BUTTON OPERATION LAMP (RED) TIMER ON/OFF BUTTON...
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B Installation FCQ-B7 Number Description Indoor unit Outdoor unit Remote controller Inlet air Discharged air Refrigerant piping, connection electric wire Drain pipe Ground wire Wire to ground from the outdoor unit to prevent electrical shocks.