2. Copier-specific Adjustments

2.1.1 To Adjust the Copy Image Quality in the Black Mode

* You can start with any of the procedures. But it is recommended to perform the procedures in order, as listed
below. You can use one procedure in conjunction with another. But if this changes the image quality more
than required or loses the effectiveness of the adjustment, restore the settings made in the previously used
procedure to the original ones. Then use other procedures.
* Both the service technician and the user can use procedures (1), (2) and (4).
* Only the service technician must use procedures (3), (5) and (6).
(1) Press the [BASIC] button on the Control Panel. Press the [
After increasing the copy density, copy and check the copy image quality.
With the copy density set to the maximum, if further image quality adjustments are still necessary, use the
next procedure.
(2) Press the [IMAGE] button on the Control Panel. Press the [SHARPNESS] button.
Press the [SHARP] button to increase the sharpness intensity.
After increasing the sharpness intensity, copy and check the copy image quality.
With the sharpness intensity set to the maximum, if further image quality adjustments are still necessary, the
service technician must use the following procedures.
(3) Enter adjustment mode [05]. Increase the values for codes [7056] to [7058] and [7806] to [7809] to make
the copied text darker (sharpness level increases).
• The code to use varies according to the original mode (Text/Photo, Text or Photo). Adjust the value for
[05] code corresponding to the original mode in which you would like to improve the image quality and set
values larger than "128".
Original mode
Text / Photo
Text
Photo
Image smoothing
Auto color (when
judged as black)
Text/Photo
Auto color (when
judged as black)
Text
Auto color (when
judged as black)
Photo
* Setting "0" provides the softest image, while setting "255" provides the sharpest image.
Changing the values for these codes will change the sharpness intensity, when the "Sharpness" indicator in
the "IMAGE" menu is set to the center. Remember that 1 step of the indicator will increase or decrease the
sharpness intensity by 25. If the sharpness intensity of the center value is changed, each step of the indicator
will be changed accordingly. (For instance, if the center value is increased by 25 (sharper), the value of each
step of the indicator will also be increased by 25 (sharper).)
e-STUDIO2040C/2540C/3040C/3540C/4540C
Recommended
[05] code
value
05-7056
05-7057
05-7058
05-7809
05-7806
Set a value larger than
128.
05-7807
05-7808
© 2011 TOSHIBA TEC CORPORATION All rights reserved
2 - 2
] button to increase the copy density.
Acceptable
value range
0 to 255
Default
128