Tube-Enclosed Heating Element; Fill Solenoid Valve (If Featured) - Atag VA6111AF Manual

Hide thumbs Also See for VA6111AF:
Table of Contents

Advertisement

7.9 Tube-enclosed heating element

(a) Remove any residual water from the sump by suction so that it does not flow into the tub and the
pressure switch tubes when the appliance is laid on the rear panel.
(b) Remove the plinth and the lower front panel (see 1.2), the bottom panel (see 1.3), the anti-flooding
device (see 6.1) (if featured), and the right-hand lateral panel (see 1.4), then lay the appliance on the
rear panel.
(c) Detach the electrical connections.
(d) From the right-hand side, detach the hose connected to
external manifold.
(e) From below, detach the hose connected to the sump.
(f) Form the right-hand side, slide out the heating element.
When replacing:
Ensure that the hoses are fitted correctly and that the hose clamps are secured tightly.

7.10 Fill solenoid valve (if featured)

(a) Disconnect the appliance from the water supply.
Unscrew the fill hose from the solenoid valve.
Important: residual water may spill from the hose.
(b) Remove the two rear screws which secure the valve to
the base.
(c) Remove the worktop (see 1.1), the plinth, the lower
front panel (see 1.2) and the left-hand lateral panel (see
1.4) and detach the solenoid valve from the hose to the
water fill tank.
(d) From the left-hand side, grip the solenoid valve and,
while at the same time pushing it from the rear, turn it
clockwise until it is released.
SOI/TD - PR
(d)
(e)
23
(b)
(d)
599 38 70-09

Advertisement

Table of Contents
loading