(d) When remounting, place the wiring accurately taking
care not to damage the plastic parts and that the wiring
do not come into contact with the warm or live
components which are fitted inside the appliance (for
ex. water fill solenoid, heating element...); ensure that
the board housing is fitted properly to the plastic
support.

5.9 Thermostat/temperature and turbidity control sensor

(a) First, remove the plinth and the lower front panel (see 1.2).
(b) Enlarge the sump hooks and slide the thermostat.
(c) Remove the electrical connectors.
When replacing:
When replacing the thermostat, first lubricate the seal and then position it correctly on the sensor. Insert the
assembled parts taking care to ensure that the seal does not enter the sump.
Important: Check that the anchor tabs return to their original position!
5.10 Regeneration solenoid valve (if featured)
(a) First remove the plinth and the lower front panel (see 1.2).
Important: The softening system will contain a quantity of water.
Before removing the solenoid valve, this water should be removed by suction.
(b) Turn the solenoid valve counter-clockwise until it exits its housing.
(c) Remove the connectors.
When replacing:
When replacing the solenoid valve, lubricate the O-ring and position it correctly on the valve; insert the valve
into the seat and turn clockwise until is locks into position.