Installation distance to walls and ceiling

C11
Important!
The dimension diagrams only show the minimum
permitted installation distances for the insert. When
connecting to a steel flue, also note the safety distance
requirements of the flue. The safety distance between an
Combustible roof
*If the wood compartment is to be placed between the surround and the wall at least 465 / 610 mm is required.
uninsulated flue and a combustible part of the building
should be at least 300 mm. The minimum distance to
combustible parts of the building or interior decoration in
front of the insert must be at least 1.5 m.
1050
400*
925
INSTALLATION DISTANCES
620
265
Utv. Ø 200
120
GB
43