Download Print this page

Installation Distances - Contura C 650 Installation Instruction

Hide thumbs Also See for C 650:

Advertisement

GB
72

INSTALLATION DISTANCES

Installation distances
C 650
Combustible roof
555
Combustible wall
640
Permitted
area for
combustible
400
parts of the
building
520
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to
separate glass hearth plates (accessory).
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
WHEN INSTALLING TURNTABLE (OPTION) the
following installation distances do not apply.
See the separate turntable installation instruc-
tions.
Air inlet Ø64
300
200
100
Combustible wall
800
480
Ø150
40
100
Air inlet Ø64
630
Fire-retardant wall of
brick or concrete
615
700
Fire-retardant wall of
brick or concrete
120* (520)
400
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
When top connecting a steel flue,
please refer to the particular
manufacturer's installation
instructions. Observe the safety
distance to combustible material
required by the steel flue
A = height from floor to
chimney connection upwards
B = height from floor to c/c
chimney connection rear
C = height from floor to air inlet
D = height from floor to bottom
edge door
E = height from floor to upper edge
of hatch
!
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney
by 10 mm. The spacers
supplied with the hearth
plate are installed on the
stove before connection.