Installation distances

Important!
The dimension diagrams only show the minimum permitted
installation distances for the stove. When connecting to a
steel chimney, the requirements for safe distance to the
500
chimney must also be observed. A clearance of at least 1 m
must be allowed as a safe distance between the front of the
stove and combustible building elements or furnishings.
Combustible roof
590
Ci61 / Ci61A / Ci61AN / Ci61T
!
If the stove is to be positioned against a
combustible rear wall, the wall must be
protected by an external firewall or the
integrated protective screen (available as
an optional accessory in some markets).
The material requirements for the
firewall are specified in the section "Walls
behind" on page 100
GB
103
INSTALLATION DISTANCES