Download Print this page

Installation Distance To Walls And Ceiling - Contura C 35 Installation Instruction

Hide thumbs Also See for C 35:

Advertisement

Installation distance to walls and ceiling

C 35
Combustible roof
Combustible wall
Fire-retardant wall of
brick or concrete
*To prevent discolouration of painted fire walls, we recommend the same side distance as to combustible walls.
550
Air inlet Ø64
900
430
167
Hole in foot plate Ø120
120
Permitted area for
combustible parts
of the building
435
415
690
700
Fire-retardant wall of
brick or concrete
50*
325*
INSTALLATION DISTANCES
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
The dimension diagrams only
show the minimum permitted
installation distances for the
stove. When connecting to a steel
flue, also note the safety distance
requirements of the flue. The
safety distance between an un-
insulated flue and a combustible
part of the building should be at
least 300 mm.
Combustible wall
GB
69

Advertisement

loading