Installation Distances - Contura C 556 Installation Instruction

Advertisement

GB
56

INSTALLATION DISTANCES

Installation distances
C 556
Combustible roof
495
Permitted
area for
combustible
parts of the
building
500
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to
separate glass hearth plates (accessory).
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
WHEN INSTALLING TURNTABLE (OPTION) the
following installation distances do not apply.
See the separate turntable installation instruc-
tions.
400
Combustible wall
695
450
350
250
150
Combustible wall
750
440
140
Ø150
35
100
800
Fire-retardant wall of
brick or concrete
565
700
Fire-retardant wall of
brick or concrete
70**
320**
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
When top connecting a steel flue,
please refer to the particular
manufacturer's installation
instructions. Observe the safety
distance to combustible material
that the steel flue requires.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
Air inlet Ø67
!
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney
by 10 mm. The spacers
supplied with the hearth
plate are installed on the
stove before connection.