Installation distances

C820T
Combustible roof
460
Combustible wall
50
Permitted
area for
combustible
300
material
200
100
350
580
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to
separate glass hearth plates (accessory).
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
WHEN INSTALLING TURNTABLE (OPTION) the
following installation distances do not apply.
See the separate turntable installation instruc-
tions.
Combustible wall
360
Ø150
180
45
Air inlet Ø67
115
Fire-retardant wall of
brick or concrete
50
700
Fire-retardant wall of
brick or concrete
50**
280**
INSTALLATION DISTANCES
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
The dimension diagrams only
show the minimum permitted
installation distances for the
stove. When connecting to a steel
flue, also note the safety distance
requirements of the flue. The
safety distance between an un-
insulated flue and a combustible
part of the building should be at
least 450 mm.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
A separate glass hearth
!
plate (accessory)
increases the connection
height to the chimney by
6 mm.
GB
55