See rating plate on the insert Intended area of use Heating of rooms in residential buildings Fuel Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard...
A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new insert. As a new owner of a Contura insert, you have secured a product with timeless design and long service life.
Walls behind This manual contains instructions about Before installing a firebox or erecting a If your Contura i51 is to be installed how to assemble and install the Contura chimney, it is necessary for you to make against a combustible wall, the wall i51.
CHIMNEY Chimney The stove is type approved in accordance with EN 13240 and the Carefully check that the chimney is sealed and that there is no values obtained are presented in the Performance declaration, leakage around soot hatches and flue connections. external diameter of the connection is Ø150 mm.
SUPPLY Supply of combustion air Supply of combustion must be provided. Combustion air can be provided directly via a duct from outside, or indirectly via a vent in the outer wall of the room where the stove is placed. The amount of combustion air that is used for combustion is approx.
INSTALLATION DISTANCES Installation distances C i51 Important! The dimension diagrams only show the minimum permitted the flue. The minimum distance to combustible parts of the installation distances for the stove. When connecting to a building or interior decoration in front of the stove must steel flue, also note the safety distance requirements of be at least 1.5 m.
Page 8
INSERT PLACEMENT 8 mm Allen screw 4 Allen screw 3 10 mm 13 mm...
INSERT PLACEMENT Placement and adjustment of the insert If the protective screen is selected – read these instructions before installing the insert or chimney. 10 mm M6 x 20 Allen 10...
Page 10
INSERT PLACEMENT The stove can be positioned tight to the wall behind. When installing against non-vertical walls and to facilitate installation it is recommended that a small gap is left between the wall and stove. Lay the floor section a slight distance from the wall behind, and align the position of the holes in the ceiling for the chimney lead-in with the same dimensions.
Page 11
INSERT PLACEMENT 13 mm 13 mm Place a spirit level on the moulding below the door, adjust the feet until the smallest dimension from the floor to the underneath of the moulding is 505 mm all the way around. Move the spirit level to the sides and check that it is straight.
Page 12
INSERT PLACEMENT The protective screen must be installed before the chimney. Check that the transport locking device • With protective screen as option – of the counterweight is removed now connect according to separate instructions. according to the insert instructions •...
Page 13
INSTALLATION OF SURROUND Installation of surround Pre-installation of lower cover - section 1. Nut M5 Tool 8 mm Nut M5 Tool 8 mm 90° Nut M5 Tool 8 mm...
Page 14
INSTALLATION OF SURROUND Pre-installation of side panels - section 2 M6 x 25 Allen screw 4 Tool 10 mm Spacers Pre-installation of upper cover - section 3 Nut M5 Tool 8 mm 90° M6 x 16 Allen screw 4...
Page 15
INSTALLATION OF SURROUND Tool 10 mm M6 x 25 M6 x 25 Allen screw 4 Allen screw 4 Pre-installation of upper cover - section 4 Nut M5 Tool 8 mm 90° M6 x 16 Allen screw 4...
Page 16
INSTALLATION OF SURROUND Nut M5 M5 x 12 Tool 8 mm Allen screw 3...
Page 17
INSTALLATION OF SURROUND Nut M5 tool 8 mm 8 mm...
Page 26
INSTALLING GRATE AND TOP Adjust the rubber feet on the disc base so that the gap up to the steel panels is 5 mm. Final inspection of the installation It is extremely important that the installation is inspected by an authorised inspection body before the stove is used.
Page 28
NIBE AB · Box 134 · SE-285 23 · Markaryd · Sweden www.contura.eu Contura reserves the right to change dimensions and procedures described in these instructions at any 811269 IAV SE-EX Ci51 Plåt-3 time without special notice. The current edition can be 2015-11-24 downloaded from www.contura.eu...