Draining The Boiler On The Dhw Side - Viessmann Vitodens 222-F B2TA Installation And Service Instructions Manual

Hide thumbs Also See for Vitodens 222-F B2TA:
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Further details regarding the individual steps

Draining the boiler on the DHW side

1. Connect hose to drain valve and
route into a suitable container or drain
outlet.
Note
Ensure adequate ventilation in the
DHW pipework.
58
(cont.)
2. Turn drain valve from lever position
A (operational) to lever position B
or C as required.
■ Lever position B: Drain drinking
water circuit in appliance exclud-
ing DHW cylinder via the cold
water connection.
■ Lever position C: Drain drinking
water circuit in appliance and DHW
cylinder via the DHW connection.
The cold water connection remains
filled.