Viessmann Vitodens 222-F B2TA Installation And Service Instructions Manual page 127

Hide thumbs Also See for Vitodens 222-F B2TA:
Table of Contents

Advertisement

Fault codes
(cont.)
Dis-
Const.
played
fault
code
bE
bF
C1
X
C3
X
C4
X
C5
X
Weath.-
System char-
comp.
acteristics
X
Control mode
without remote
control
X
Control mode
X
Control mode
X
Control mode
X
Control mode
X
Control mode,
max. pump
speed
Troubleshooting
Cause
Measures
Communica-
Check connec-
tion error, re-
tions, cable, coding
mote control
address "A0" in
Vitotrol heat-
group "Heating
ing circuit 3
circuit..."/5 and re-
(with mixer)
mote control con-
figuration (see
page 166).
For wireless re-
mote controls:
Check connec-
tions, place remote
control unit close to
the boiler
Incorrect
Replace LON com-
LON commu-
munication module
nication mod-
ule
Communica-
Check connec-
tion error, ex-
tions
tension EA1
Without exten-
sion EA1:
Set code "5b:0" in
group "General"/1
Communica-
Check connec-
tion error, ex-
tions
tension AM1
Without extension
AM1:
Set code "32:0" in
group "General"/1
Communica-
Check OpenTherm
tion error,
extension
OpenTherm
extension
Communica-
Check coding ad-
tion error, var-
dress setting "30"
iable speed
in group "Boiler"/
internal pump
2
127

Advertisement

Table of Contents
loading

Table of Contents