Viessmann Vitodens 222-F B2TA Installation And Service Instructions Manual page 132

Hide thumbs Also See for Vitodens 222-F B2TA:
Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Dis-
Const.
played
fault
code
EA
X
Eb
X
EC
X
Ed
X
132
Weath.-
System char-
comp.
acteristics
X
Burner in a fault
state
X
Burner in a fault
state
X
Burner in a fault
state
X
Burner in a fault
state
Cause
Measures
Ionisation
Check flue system;
current out-
remedy flue gas re-
side permissi-
circulation if re-
ble range dur-
quired.
ing calibration
In open flue opera-
(deviation
tion, prevent high
from previous
incidence of dust in
level too
the combustion
great)
air.
Press reset button
R
Following several
unsuccessful reset
attempts, replace
boiler coding card
and press reset
button R
Repeated
Check gap be-
flame loss
tween ionisation
during cali-
electrode and
bration
burner gauze as-
sembly (see
page 52).
Check allocation of
gas type (see
page 52).
Check flue system;
remedy flue gas re-
circulation if re-
quired.
Press reset button
R
Parameter
Press reset button
fault during
R or
calibration
Replace boiler cod-
ing card and press
reset button R
Internal fault
Replace control
unit