Hard disk drives / solid state drives
7.2.7
Replacing a 2.5-inch HDD/SSD module
Customer Replaceable Unit
(CRU)
Tools: tool-less
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
●
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see section
hot-plug HDD/SSD module" on page
Under no circumstances should you remove an HDD/SSD module
●
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD/SSD modules (drives) must be uniquely identified so that
●
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
7.2.7.1
Preliminary steps
"Locating the defective server" on page 45
Ê
"Locating the defective component" on page 47
Ê
Only applicable for removing intact HDD/SSD modules:
Ê Before removing a non-defective HDD/SSD module, put the drive into
"Offline" mode using your RAID configuration software.
7.2.7.2
Removing the defective 2.5-inch HDD/SSD module
Ê Remove the HDD/SSD module as described in section
HDD/SSD modules" on page
128
126.
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Indicators on the
369.
"Removing 2.5-inch
RX2530 M1